CATEGORY 06 • CRITICAL ROOM PROTECTIONVery Early Smoke Detection & Critical Environment Protection

VESDA

Continuous air-sampling aspirating smoke detection systems engineered for early warning in high-airflow data centres and critical rooms.

STANDARDS:EN 54-20 where applicableNFPA 72 where applicableApplicable fire detection & life-safety requirementsLocal statutory requirements as designed
Enterprise aspirating smoke detection VESDA system installed in a mission-critical server room with rigid sampling pipes and calibrated capillary sampling points
EN 54-20 / NFPA 72
TURNKEY DEPLOYMENT
DisciplineVery Early Smoke Detection & Critical Environment Protection
Service ModeSupply, Installation, Testing & Commissioning
SUBSYSTEM ARCHITECTURE & CAPABILITIES

Engineered Subsystem Scope & Architecture

Hornet Infotech delivers end-to-end engineering for VESDA across enterprise commercial campuses, IT/ITES facilities, manufacturing plants, and mission-critical environments. Every deployment is coordinated with building MEP pathways, structural containments, and cross-subsystem event trigger matrices.

High-sensitivity laser detection chamber detecting early smoldering aerosols
Calibrated engineered sampling pipe networks installed in ceiling voids and raised floors
Multi-stage alarm escalation (Alert, Action, Fire 1, Fire 2) preventing false gas discharge
Seamless Modbus/Relay communication with main Fire Alarm panels and BMS monitoring
TURNKEY DEPLOYMENT GUARANTEE

All equipment installations undergo calibrated test procedures, signal-integrity verification, and documented sign-off before client handover.

Aspirating smoke detection unit and sampling pipework with air filter assembly mounted beside server rack enclosure in a clean telecom data facility
SUBSYSTEM TOPOLOGY & FIELD DEPLOYMENT
Protected Space → Sampling Points → Pipe Network → Dual-Stage Filtration → Detection Core
HORNET INTEGRATION DISCIPLINE

System Parameters

CategoryCRITICAL ROOM PROTECTION
DisciplineVery Early Smoke Detection & Critical Environment Protection
Deployment ModeTurnkey Supply, Installation, Testing & Commissioning
Post-Handover SupportAMC & Preventive Maintenance
PROVEN FIELD EXECUTION

Documented Project Deployments

Verified enterprise and institutional infrastructure deployments demonstrating HORNET INFOTECH's turnkey delivery.

COMPLETE PROJECTS ARCHIVE
HNT-PRJ-001Commissioned & Handed Over
Katihar, Bihar

AL-Karim University Campus ICT & ELV Infrastructure

Turnkey campus-wide ELV and ICT infrastructure across the 55-acre AL-Karim University campus in Katihar, Bihar, encompassing approximately 450–500 km of structured cabling, 35 km fibre infrastructure, 1,800+ data points, 1,000+ wireless access points, 500+ IP telephony endpoints, 8 flap barriers, data centre setup, AV conferencing, and environmental detection systems (VESDA, water leak detection, rodent detection).

FACILITY SCALE: 55-Acre University Campus (~50–55 Buildings)
VIEW VERIFIED PROJECT DOSSIER
HNT-PRJ-002Phase 1 • Handed Over
Chandigarh, Punjab

eClerx Corporate Facility ELV & ICT Infrastructure (Phase 1)

Integrated ELV, electronic security, life safety, and network cabling infrastructure deployed for eClerx Chandigarh (Phase 1), supporting 216 CCTV surveillance cameras, a 340-device addressable fire alarm system, 170 PA speakers/units, 30 access-controlled doors, 1,500+ structured cabling data points, Novec clean-agent suppression, VESDA, WLD, and rodent detection.

FACILITY TYPE: Corporate Facility
VIEW PHASE 1 DOSSIER
HNT-PRJ-003Phase 2 • Handed Over
Chandigarh, Punjab

eClerx Corporate Facility ELV & ICT Infrastructure (Phase 2)

Integrated ELV, electronic security, life safety, and network cabling infrastructure deployed for eClerx Chandigarh (Phase 2), supporting 178 CCTV surveillance cameras, a 215-device addressable fire alarm system, 120 PA speakers/units, 23 access-controlled doors, 1,000+ structured cabling data points, Novec clean-agent suppression, VESDA, WLD, and rodent detection.

FACILITY TYPE: Corporate Facility
VIEW PHASE 2 DOSSIER