HOME/PROJECTS/HNT-PRJ-002
┌ FIELD_DOSSIER_COVER
REGISTRY_NO. HNT-PRJ-002 ┐
PROJECT RECORD • HNT-PRJ-002Fire & Life Safety • Security & Access • Network & Data • Mission-Critical Infrastructure

eClerx Corporate Facility ELV & ICT Infrastructure (Phase 1)

CHANDIGARH, PUNJAB
•
CORPORATE OFFICES & COMMERCIAL BUILDINGS
•ENTERPRISE SYSTEMS INTEGRATION
HORNET INFOTECH • ENGINEERING RECORD BRIEF

Integrated ELV, electronic security, life safety, and network cabling infrastructure deployed for eClerx Chandigarh (Phase 1), supporting 216 CCTV surveillance cameras, a 340-device addressable fire alarm system, 170 PA speakers/units, 30 access-controlled doors, 1,500+ structured cabling data points, Novec clean-agent suppression, VESDA, WLD, and rodent detection.

+
PROJECT PHOTOGRAPHY ARCHIVEFIELD MEDIA SUBJECT TO CLIENT CLEARANCE
SPECIFICATION: DOCUMENTEDRECORD REF: HNT-PRJ-002

02 • PROJECT REGISTER • TECHNICAL SPECIFICATION

OFFICIAL RECORD
REGISTER FIELDVERIFIED RECORD VALUE
PROJECT IDHNT-PRJ-002
CLIENT / CLEARANCEeClerx
LOCATIONChandigarh, Punjab
SCALE & COMPLEXITYPhase 1 deployment supported 216 CCTV surveillance cameras, a 340-device addressable fire alarm system, 170 PA speakers/units, 30 access-controlled doors with 13 exit bars and 23 emergency door release interfaces, along with 1,500+ structured cabling data points, Novec clean-agent suppression, VESDA early warning detection, water leak detection, and rodent detection.
FACILITY TYPECorporate Facility
INDUSTRY / SECTORCorporate Offices & Commercial Buildings
PROJECT CATEGORIESFire & Life Safety, Security & Access, Network & Data, Mission-Critical Infrastructure
PROJECT / CONTRACT MODELEnterprise Systems Integration
PROJECT STATUSCommissioned & Handed Over
VERIFICATION STATUSPublic Engineering Case

03 • PROJECT BRIEF • FACILITY ENVIRONMENT & REQUIREMENTS

Operational Requirement & Context

Deployment across eClerx corporate facility in Chandigarh, Punjab (Phase 1), requiring integrated addressable fire detection, public address, IP surveillance, door access control with panic hardware and emergency releases, Novec clean-agent suppression, early warning aspirating smoke detection, critical environmental monitoring, active networking, and structured cabling.

PUBLICATION-SAFE DESCRIPTION (NDA CLEARED)

HORNET INFOTECH engineered and deployed ELV, electronic security, fire-life safety, and network cabling infrastructure for eClerx Chandigarh (Phase 1). The scope covered comprehensive fire alarm, public address, access control with egress releases, IP surveillance, clean-agent suppression, and mission-critical environmental protection across 1,500+ structured cabling data points.

04 • HORNET SCOPE REGISTER

DELIVERY CATEGORIES
SCOPE 03

Hardware & OEM Procurement

  • •340 addressable fire alarm system devices
  • •170 PA speakers/units
  • •30 access control door hardware sets
  • •216 CCTV surveillance cameras
  • •13 door exit bars and panic hardware
  • •23 emergency door release units
  • •Structured cabling components for 1,500+ structured cabling data points
  • •Novec clean-agent fire extinguishing equipment
  • •VESDA aspirating smoke detection, water leak detection (WLD), and rodent detection hardware
  • •Active networking equipment
SCOPE 04

On-Site Installation & Cabling

  • •Installation of 340 fire alarm system devices
  • •Installation of 170 PA speakers/units
  • •Installation of 30 door access control points
  • •Installation of 216 CCTV surveillance cameras
  • •Installation of 13 door exit bars and 23 emergency door releases
  • •Installation of 1,500+ structured cabling data points
  • •Installation of Novec clean-agent suppression system
  • •Installation of VESDA aspirating detection, water leak detection, and rodent detection
  • •Deployment of active networking and structured cabling
SCOPE 05

Multi-Vendor Systems Integration

  • •Integration of fire alarm and life safety systems
  • •Public address and emergency voice integration
  • •Access control integration with emergency door releases and exit hardware
  • •CCTV surveillance monitoring integration
  • •Server room critical protection integration (Novec, VESDA, WLD, rodent detection)
  • •Active networking and structured cabling connectivity

05 • DELIVERED SYSTEMS & SCHEMATIC ANCHORS

10 SUBSYSTEMS
SUBSYSTEM S-01

Fire Alarm System

340 addressable fire alarm system devices deployed across the corporate facility.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-02

Public Address & Voice Alarm

170 PA speakers/units for public address and emergency communication.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-03

Access Control & Egress Hardware

30 access-controlled doors with 13 exit bars / panic hardware and 23 emergency door release interfaces.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-04

CCTV & IP Surveillance

216 CCTV surveillance cameras providing facility-wide visual security.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-05

Structured Cabling Infrastructure

1,500+ structured cabling data points for workstations and facility systems.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-06

Active Networking

Active networking equipment supporting facility data communications and IP subsystems.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-07

Novec Clean-Agent Suppression

Novec clean-agent gaseous fire suppression for critical equipment protection.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-08

VESDA Aspirating Smoke Detection

Very Early Warning aspirating air-sampling detection for critical areas.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-09

Water Leak Detection (WLD)

Water leak detection system for critical room environmental monitoring.

CANONICAL SOLUTION SCHEMATIC
SUBSYSTEM S-010

Rodent Detection System

Rodent detection and deterrence system protecting cable pathways and equipment spaces.

CANONICAL SOLUTION SCHEMATIC

07 • TECHNICAL DRAWINGS • ENGINEERING EVIDENCE

CAD / SCHEMATICS / HIGHLIGHTS
REGISTERED SCHEMATICS & SINGLE-LINE EXTRACTS:
2nd Floor Tower A & B Access SystemECL-CHD-P1-DWG-01
Door Access Control & Egress Release Layout (2nd Floor, Tower A & B)

Technical layout identified as the eClerx Chandigarh 2nd Floor Tower A & B Access System drawing, documenting door access control and egress release scope.

Fire Alarm System Layout — 2nd FloorECL-CHD-P1-DWG-02
Intelligent Addressable Fire Alarm Layout (GOOD FOR CONSTRUCTION)

Technical layout identified as the eClerx Chandigarh 2nd Floor Fire Alarm System Layout, marked GOOD FOR CONSTRUCTION.

ENGINEERING HIGHLIGHTS & FIELD METRICS
  • •Surveillance Scale: 216 CCTV surveillance cameras
  • •Life Safety Network: 340-device addressable fire alarm system
  • •Public Address: 170 PA speakers/units
  • •Access Control & Egress: 30 access-controlled doors with 13 exit bars and 23 emergency door release interfaces
  • •Structured Cabling: 1,500+ structured cabling data points
  • •Critical Protection: VESDA, water leak detection, rodent detection, and Novec clean-agent protection
12 • PROJECT INQUIRY

DISCUSS A SIMILAR ENGINEERING REQUIREMENT

Connect with HORNET INFOTECH systems engineers to review ELV, ICT, fire & life safety, and critical facility schematics tailored to your deployment specifications.

HORNET INFOTECH

J-50, Abul Fazal Enclave, Okhla, New Delhi-110025