CATEGORY 02 • FIRE & LIFE SAFETYFire Detection & Life Safety Systems

Fire Alarm Systems

Engineered addressable and conventional fire detection systems, alarm initiation devices, synchronized audiovisual notification, programmable cause-and-effect matrix control, emergency system interfaces, and end-to-end lifecycle maintenance.

STANDARDS & PROTOCOLS:Addressable & Conventional DetectionEN 54 / NFPA 72 Standards (where applicable)Local Authority & Statutory Compliance
Enterprise addressable fire alarm control panel installation in commercial facility security control center
Addressable Fire Life Safety
Monitored Loop Architecture
CategoryFire & Life Safety
DisciplineFire Detection & Life Safety Systems
Deployment ModeTurnkey Supply, Installation, Testing & Commissioning
Post-Handover SupportAMC & Preventive Maintenance
Direct Engineering Desk:+91 8920700133
SUBSYSTEM TOPOLOGY

Engineered Subsystem Scope & Architecture

HORNET INFOTECH designs, supplies, installs, tests, and commissions integrated fire detection and life-safety systems. From initiating field sensors and intelligent loop processing to multi-tier notification and emergency building interfaces, every subsystem is engineered for life-safety reliability.

Addressable fire alarm control panel interior with loop cards, battery backup, fire-rated cabling, and initiating modules
FIRE-ALARM SIGNAL CHAIN
Fire Detection → Initiating Device → Fire Alarm Control Panel → Cause & Effect Logic → Notification / Alarm → Monitoring → Emergency Interfaces
Multi-Loop Addressable Fire Alarm Panels (FACP) & Networking

Microprocessor-controlled addressable fire alarm control panels supporting expandable Class A or Class B loops, peer-to-peer panel networking, redundant power supplies, battery autonomy calculations, and non-volatile event logging.

Intelligent Optical, Heat & Specialized Detectors

Point-addressable optical smoke, rate-of-rise thermal, and multi-criteria sensors with drift compensation and dirty-head alerts; complemented by high-sensitivity aspirating smoke detection (ASD) and projected optical beam detectors for expansive halls.

Manual Call Points (MCPs) & Supervised Loop Modules

Resettable break-glass/push manual call points (MCP), supervised input monitor modules for sprinkler flow switches and pressure switches, and control relay modules for fire damper, AHU plant shutdown, and emergency door release.

Notification Appliances, Annunciators & Central Monitoring

Supervised multi-tone electronic sounders, synchronized xenon/LED strobes, voice alarm evacuation integration, floor-level LCD repeater annunciators, and high-level BACnet/Modbus gateway integration into central BMS workstations.

ECOSYSTEM HARMONIZATION

Fire Alarm Integration with the HORNET Ecosystem

Fire alarm systems form the statutory foundation of facility life safety. HORNET coordinates initiating devices, central panel processing, multi-zone notification, and emergency building interlocks subject to applicable codes and project design.

01
Initiating Capture

Fire Detection

Addressable optical smoke, rate-of-rise heat, and multi-sensor detectors monitoring ambient air.

02
Human Input

Manual Initiation

Break-glass and push-type addressable manual call points (MCP) and monitored emergency inputs.

03
Loop Analysis

Intelligent Processing

Microprocessor fire alarm control panel evaluates analogue loop values and verifies fire condition.

04
Decision Engine

Cause & Effect Logic

Site-specific programmable matrix mapping initiating zones to designated output actions as designed.

05
Audible & Visual

Alarm Notification

Multi-tone electronic sounders, synchronized flashing strobes, and voice alarm broadcast where applicable.

06
Control & Telemetry

Monitoring & Annunciation

LCD repeater panels, graphical workstation floorplan display, and central BMS supervisory signaling.

07
Life Safety Linkage

Emergency Interfaces

Supervised relays for HVAC AHU tripping, fire dampers, access door unlocking, and lift grounding recall.

FACILITY PROFILES

Deployment Environments

Every facility architecture imposes unique fire-loading profiles, occupancy patterns, zoning subdivisions, and statutory evacuation codes. HORNET engineers systems tailored to specific building typologies.

Corporate & Commercial Buildings

Multi-story addressable loop zoning, floor-by-floor phased evacuation notification, tenant demarcation modules, and emergency staircase pressurization interlocks as designed.

IT / ITES & Technology Campuses

High-sensitivity aspirating smoke detection (ASD) for server halls, intelligent multi-criteria sensors across work areas, and networked peer-to-peer fire panels across multiple campus blocks.

Manufacturing & Industrial Facilities

Heavy-duty optical beam detectors for high-bay warehouse roofs, linear heat detection (LHD) for cable trays, flame detectors, and weatherproof outdoor manual call points where applicable.

Healthcare Facilities & Hospitals

Cause-and-effect horizontal compartment evacuation schemes, patient ward sounder tone adjustments, nurse station repeater annunciators, and medical gas room monitoring.

Government & Institutional Campuses

Centralized fire graphics workstations, multi-building fiber-optic network loops, public auditorium voice evacuation interfaces, and statutory authority compliance documentation.

Mission-Critical & Data Facilities

Early warning air sampling detection, dual-knock cross-zone releasing circuits for gas suppression integration, UPS battery room hydrogen monitoring, and 24/7 BMS telemetry.

PROJECT TENDER SPECIFICATIONS & BOQ CONSULTING

Detailed Technical Specifications in Preparation

Comprehensive fire alarm datasheets, addressable loop calculations, device coverage layouts, cable containment pathways, and equipment Bill of Quantities (BOQ) are tailored by our engineering team to client architectural blueprints and statutory fire authority requirements.

Fire alarm system BOQ preparation
Detector & initiating-device technology selection
Loop and zone architecture design
Device quantity & coverage planning
Cable & fire-rated containment coordination
Fire alarm control panel & repeater selection
Battery backup calculations & autonomy sizing
Cause-and-effect matrix programming coordination
Emergency HVAC, damper & door interface coordination
Testing, commissioning & authority handover
OFFICIAL ENGINEERING DESK
HORNET INFOTECH
J-50, Abul Fazal Enclave, Okhla, New Delhi-110025
+91 8920700133
contact@hornetindia.com
Single contract accountability for ELV, ICT & Fire Life Safety.
PROVEN FIELD EXECUTION

Documented Project Deployments

Verified corporate infrastructure delivered, commissioned, and handed over by HORNET INFOTECH.

COMPLETE PROJECTS ARCHIVE
HNT-PRJ-002Phase 1 • Handed Over
Chandigarh, Punjab

eClerx Corporate Facility ELV & ICT Infrastructure (Phase 1)

Integrated ELV, electronic security, life safety, and network cabling infrastructure deployed for eClerx Chandigarh (Phase 1), supporting 216 CCTV surveillance cameras, a 340-device addressable fire alarm system, 170 PA speakers/units, 30 access-controlled doors, 1,500+ structured cabling data points, Novec clean-agent suppression, VESDA, WLD, and rodent detection.

FACILITY TYPE: Corporate Facility
VIEW PHASE 1 DOSSIER
HNT-PRJ-003Phase 2 • Handed Over
Chandigarh, Punjab

eClerx Corporate Facility ELV & ICT Infrastructure (Phase 2)

Integrated ELV, electronic security, life safety, and network cabling infrastructure deployed for eClerx Chandigarh (Phase 2), supporting 178 CCTV surveillance cameras, a 215-device addressable fire alarm system, 120 PA speakers/units, 23 access-controlled doors, 1,000+ structured cabling data points, Novec clean-agent suppression, VESDA, WLD, and rodent detection.

FACILITY TYPE: Corporate Facility
VIEW PHASE 2 DOSSIER
PORTFOLIO DIRECTORY

Explore All Hornet Solutions

Full Directory Index
FIRE & LIFE SAFETYCode-compliant addressable fire detection, clean-agent gas suppression, and emergency life safety systems.